{"product_id":"chargepapa-stationcheck-ac-evse-diagnostic-simulator","title":"ChargePapa StationCheck | Simulador de diagnóstico de CA EVSE","description":"\u003cdiv class=\"cp-product-description\" style=\"font-family:Arial,Helvetica,sans-serif;color:#111827;line-height:1.55;\"\u003e\n\n  \u003csection style=\"background:#f5f7f4;border:1px solid #dbe5dd;border-radius:18px;padding:22px;margin-bottom:18px;\"\u003e\n    \u003cp style=\"font-size:13px;letter-spacing:.12em;text-transform:uppercase;color:#6f8f7b;font-weight:800;margin:0 0 8px;\"\u003eSimulador de diagnóstico de EVSE de CA\u003c\/p\u003e\n\n    \u003ch2 style=\"font-size:30px;line-height:1.15;margin:0 0 10px;color:#111827;\"\u003ePruebe el punto de carga antes de culpar al coche.\u003c\/h2\u003e\n\n    \u003cp style=\"font-size:16px;color:#374151;margin:0;\"\u003eChargePapa StationCheck ayuda a instaladores, vendedores de EVSE, equipos de propiedades, operadores de flotas y equipos de soporte a verificar el comportamiento de las estaciones de carga de CA antes de usar un vehículo de cliente como primera herramienta de diagnóstico.\u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n  \u003csection style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(170px,1fr));gap:12px;margin-bottom:22px;\"\u003e\n    \u003cdiv style=\"border:1px solid #dbe5dd;border-radius:14px;padding:15px;background:#fff;\"\u003e\n\n      \u003cdiv style=\"font-size:24px;margin-bottom:8px;\"\u003e🔌\u003c\/div\u003e\n\n      \u003cstrong\u003eEVSE de CA modo 3\u003c\/strong\u003e\n      \u003cp style=\"margin:6px 0 0;color:#4b5563;font-size:14px;\"\u003ePara pruebas de estaciones de carga de CA, no para carga rápida de CC.\u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #dbe5dd;border-radius:14px;padding:15px;background:#fff;\"\u003e\n\n      \u003cdiv style=\"font-size:24px;margin-bottom:8px;\"\u003e🧪\u003c\/div\u003e\n\n      \u003cstrong\u003eSimulación CP \/ PP\u003c\/strong\u003e\n      \u003cp style=\"margin:6px 0 0;color:#4b5563;font-size:14px;\"\u003eSimula estados de VE y capacidad de corriente del cable.\u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #dbe5dd;border-radius:14px;padding:15px;background:#fff;\"\u003e\n\n      \u003cdiv style=\"font-size:24px;margin-bottom:8px;\"\u003e⚠️\u003c\/div\u003e\n\n      \u003cstrong\u003eComprobaciones PE \/ de fallos\u003c\/strong\u003e\n      \u003cp style=\"margin:6px 0 0;color:#4b5563;font-size:14px;\"\u003eAdmite pre-prueba PE, error CP y simulación de fallo a tierra.\u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #dbe5dd;border-radius:14px;padding:15px;background:#fff;\"\u003e\n\n      \u003cdiv style=\"font-size:24px;margin-bottom:8px;\"\u003e✅\u003c\/div\u003e\n\n      \u003cstrong\u003eSímbolos listados manualmente\u003c\/strong\u003e\n      \u003cp style=\"margin:6px 0 0;color:#4b5563;font-size:14px;\"\u003eCE · WEEE · Clase II \/ doble aislamiento · símbolos de advertencia de puesta a tierra.\u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003csection style=\"margin-bottom:22px;\"\u003e\n    \u003ch3 style=\"font-size:22px;margin:0 0 10px;color:#111827;\"\u003eElija la versión según el conector de la estación de carga\u003c\/h3\u003e\n\n    \u003cp style=\"margin:0 0 12px;color:#4b5563;\"\u003eStationCheck se elige según el punto de carga de CA que necesita inspeccionar. No se selecciona por marca de vehículo.\u003c\/p\u003e\n\n    \u003cdiv style=\"overflow-x:auto;\"\u003e\n\n      \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;min-width:760px;\"\u003e\n\n        \u003cthead\u003e\n\n          \u003ctr style=\"background:#1f2937;color:#fff;\"\u003e\n\n            \u003cth style=\"padding:10px;text-align:left;\"\u003eConector de estación\u003c\/th\u003e\n\n            \u003cth style=\"padding:10px;text-align:left;\"\u003eElija\u003c\/th\u003e\n\n            \u003cth style=\"padding:10px;text-align:left;\"\u003eSKU\u003c\/th\u003e\n\n            \u003cth style=\"padding:10px;text-align:left;\"\u003eCaso de uso\u003c\/th\u003e\n\n          \u003c\/tr\u003e\n\n        \u003c\/thead\u003e\n\n        \u003ctbody\u003e\n\n          \u003ctr\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eSAE J1772 \/ Tipo 1 AC EVSE\u003c\/td\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003e\u003ca href=\"\/es\/products\/chargepapa-stationcheck-ac-evse-diagnostic-simulator\"\u003eStationCheck-J\u003c\/a\u003e\u003c\/td\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eStationCheck-J-701U\u003c\/td\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eComprobaciones de estación de CA Tipo 1 de Norteamérica\u003c\/td\u003e\n\n          \u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eEstándar Europeo Tipo 2 AC EVSE\u003c\/td\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003e\u003ca href=\"\/es\/products\/chargepapa-stationcheck-ac-evse-diagnostic-simulator\"\u003eStationCheck-T2\u003c\/a\u003e\u003c\/td\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eStationCheck-T2-701E\u003c\/td\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eFlujos de trabajo de CA Tipo 2 monofásicos o trifásicos\u003c\/td\u003e\n\n          \u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eInterfaz de wallbox de CA NACS \/ estilo Tesla\u003c\/td\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003e\u003ca href=\"\/es\/products\/chargepapa-stationcheck-ac-evse-diagnostic-simulator\"\u003eStationCheck-N\u003c\/a\u003e\u003c\/td\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eStationCheck-N-701UT\u003c\/td\u003e\n\n            \u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eSolo comprobaciones de interfaz de CA NACS; no pruebas de Supercharger Tesla\u003c\/td\u003e\n\n          \u003c\/tr\u003e\n\n        \u003c\/tbody\u003e\n\n      \u003c\/table\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003csection style=\"border:1px solid #e5e7eb;border-radius:14px;padding:16px;background:#fff;margin-bottom:22px;\"\u003e\n    \u003ch3 style=\"font-size:22px;margin:0 0 10px;color:#111827;\"\u003eQué puede probar StationCheck\u003c\/h3\u003e\n\n    \u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:10px;\"\u003e\n\n      \u003cdiv style=\"background:#f9fafb;border:1px solid #e5e7eb;border-radius:12px;padding:12px;\"\u003e\n\n\u003cstrong\u003eEstados CP A \/ B \/ C \/ D\u003c\/strong\u003e\u003cp style=\"margin:5px 0 0;font-size:14px;color:#4b5563;\"\u003eSimula la conexión del VE y los estados listo para cargar.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n      \u003cdiv style=\"background:#f9fafb;border:1px solid #e5e7eb;border-radius:12px;padding:12px;\"\u003e\n\n\u003cstrong\u003eSimulación de cable PP\u003c\/strong\u003e\u003cp style=\"margin:5px 0 0;font-size:14px;color:#4b5563;\"\u003eEstados de cable NC, 13A, 20A, 32A y 63A.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n      \u003cdiv style=\"background:#f9fafb;border:1px solid #e5e7eb;border-radius:12px;padding:12px;\"\u003e\n\n\u003cstrong\u003ePre-prueba PE\u003c\/strong\u003e\u003cp style=\"margin:5px 0 0;font-size:14px;color:#4b5563;\"\u003eComprueba la presencia de voltaje peligroso en el conductor PE.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n      \u003cdiv style=\"background:#f9fafb;border:1px solid #e5e7eb;border-radius:12px;padding:12px;\"\u003e\n\n\u003cstrong\u003eError CP “E”\u003c\/strong\u003e\u003cp style=\"margin:5px 0 0;font-size:14px;color:#4b5563;\"\u003eSimula una ruta de fallo CP para observar la respuesta de la estación.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n      \u003cdiv style=\"background:#f9fafb;border:1px solid #e5e7eb;border-radius:12px;padding:12px;\"\u003e\n\n\u003cstrong\u003eSimulación de fallo a tierra PE\u003c\/strong\u003e\u003cp style=\"margin:5px 0 0;font-size:14px;color:#4b5563;\"\u003eSimula la interrupción del conductor PE.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n      \u003cdiv style=\"background:#f9fafb;border:1px solid #e5e7eb;border-radius:12px;padding:12px;\"\u003e\n\n\u003cstrong\u003eIndicador de fase\u003c\/strong\u003e\u003cp style=\"margin:5px 0 0;font-size:14px;color:#4b5563;\"\u003eTres lámparas LED indican la presencia de voltaje detectado L1 \/ L2 \/ L3.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n      \u003cdiv style=\"background:#f9fafb;border:1px solid #e5e7eb;border-radius:12px;padding:12px;\"\u003e\n\n\u003cstrong\u003eTerminales de medición\u003c\/strong\u003e\u003cp style=\"margin:5px 0 0;font-size:14px;color:#4b5563;\"\u003eAcceso a los terminales de señal L1, L2, L3, N, PE y CP para instrumentos de prueba.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n      \u003cdiv style=\"background:#f9fafb;border:1px solid #e5e7eb;border-radius:12px;padding:12px;\"\u003e\n\n\u003cstrong\u003ePrueba de disparo de GFCI\u003c\/strong\u003e\u003cp style=\"margin:5px 0 0;font-size:14px;color:#4b5563;\"\u003eAplicable a la configuración de Norteamérica \/ Tipo 1 donde sea compatible.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003csection style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(260px,1fr));gap:14px;margin-bottom:22px;\"\u003e\n    \u003cdiv style=\"border:1px solid #bbf7d0;background:#f0fdf4;border-radius:14px;padding:16px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:18px;color:#14532d;\"\u003eUtilice StationCheck cuando\u003c\/h3\u003e\n\n      \u003cul style=\"margin:0;padding-left:18px;color:#374151;\"\u003e\n\n        \u003cli\u003eNecesite comprobaciones repetibles de estaciones de carga de CA.\u003c\/li\u003e\n\n        \u003cli\u003eEsté realizando la puesta en marcha, inspección, venta o soporte de equipos EVSE.\u003c\/li\u003e\n\n        \u003cli\u003eNecesite aislar luces de fallo rojas, fallos de conexión o comportamiento de \"conectado pero sin cargar\".\u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #fed7aa;background:#fff7ed;border-radius:14px;padding:16px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:18px;color:#7c2d12;\"\u003eNo lo utilice para\u003c\/h3\u003e\n\n      \u003cul style=\"margin:0;padding-left:18px;color:#374151;\"\u003e\n\n        \u003cli\u003eCargar un VE. StationCheck no suministra energía de carga.\u003c\/li\u003e\n\n        \u003cli\u003eCarga rápida de CC, CCS, CHAdeMO o pruebas de Supercharger Tesla.\u003c\/li\u003e\n\n        \u003cli\u003eAlimentar dispositivos externos desde la toma de corriente.\u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003csection style=\"margin-bottom:22px;\"\u003e\n    \u003ch3 style=\"font-size:22px;margin:0 0 10px;color:#111827;\"\u003eGuía visual de StationCheck\u003c\/h3\u003e\n\n    \u003cp style=\"margin:0 0 12px;color:#4b5563;\"\u003eUna descripción visual rápida de la familia de productos, la selección de conectores, los controles de diagnóstico, los símbolos de seguridad, las notas de durabilidad y el contenido del paquete.\u003c\/p\u003e\n\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/01-stationcheck-ac-evse-overview.png?v=1788895604\" alt=\"ChargePapa StationCheck AC EVSE diagnostic simulator overview\" style=\"display:block;max-width:760px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/02-stationcheck-version-selector.png?v=1788895611\" alt=\"ChargePapa StationCheck connector version selector for NACS Type 2 and J1772 Type 1\" style=\"display:block;max-width:760px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/03-stationcheck-operation-elements.png?v=1788895617\" alt=\"ChargePapa StationCheck operation elements and connector labels\" style=\"display:block;max-width:760px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/04-stationcheck-testing-capabilities.png?v=1788895624\" alt=\"ChargePapa StationCheck CP PP PE and fault testing capabilities\" style=\"display:block;max-width:760px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/05-stationcheck-cp-pp-reference.png?v=1788895631\" alt=\"ChargePapa StationCheck CP and PP simulation reference table\" style=\"display:block;max-width:760px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/06-stationcheck-safety-symbols.png?v=1788895642\" alt=\"ChargePapa StationCheck manual listed safety symbols and ratings\" style=\"display:block;max-width:760px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/07-stationcheck-ip54-durability.png?v=1788895649\" alt=\"ChargePapa StationCheck IP54 durability and dry use reminder\" style=\"display:block;max-width:760px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/08-stationcheck-packing-list.png?v=1788895656\" alt=\"ChargePapa StationCheck package list\" style=\"display:block;max-width:760px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\n  \u003c\/section\u003e\n\n  \u003csection style=\"margin-bottom:22px;\"\u003e\n    \u003ch3 style=\"font-size:22px;margin:0 0 10px;color:#111827;\"\u003eImágenes de referencia de StationCheck\u003c\/h3\u003e\n\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/1_b96172b9-1bee-4df5-8b36-140f0d4117bf_480x480.png?v=1781777980\" alt=\"ChargePapa StationCheck AC EVSE diagnostic simulator reference image 1\" style=\"display:block;max-width:720px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/2_6791bcee-1eb7-443b-bf93-bda93d157b59_480x480.png?v=1781777984\" alt=\"ChargePapa StationCheck AC EVSE diagnostic simulator reference image 2\" style=\"display:block;max-width:720px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/3_b966c03e-e0aa-4871-a2b0-380be0dae91c_480x480.png?v=1781777984\" alt=\"ChargePapa StationCheck AC EVSE diagnostic simulator reference image 3\" style=\"display:block;max-width:720px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/4_480x480.png?v=1781777986\" alt=\"ChargePapa StationCheck AC EVSE diagnostic simulator reference image 4\" style=\"display:block;max-width:720px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/5_9a5c695f-ff39-4765-8985-a43d17ec122c_480x480.png?v=1781777988\" alt=\"ChargePapa StationCheck AC EVSE diagnostic simulator reference image 5\" style=\"display:block;max-width:720px;width:100%;height:auto;border:1px solid #e5e7eb;border-radius:12px;margin:0 auto 14px;background:#fff;\"\u003e\n  \u003c\/section\u003e\n\n  \u003csection style=\"border-top:1px solid #e5e7eb;padding-top:20px;margin-top:20px;\"\u003e\n    \u003ch3 style=\"font-size:22px;margin:0 0 10px;color:#111827;\"\u003eEspecificaciones completas — según manual\u003c\/h3\u003e\n\n    \u003cp style=\"margin:0 0 12px;color:#4b5563;\"\u003eLas funciones de diagnóstico compartidas se aplican a toda la familia de productos StationCheck. Las referencias de cable, tamaño y peso específicas del conector a continuación se toman del manual de StationCheck-J \/ 701U donde están etiquetadas.\u003c\/p\u003e\n\n    \u003cdiv style=\"overflow-x:auto;\"\u003e\n\n      \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;min-width:760px;\"\u003e\n\n        \u003ctbody\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"width:32%;padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eTensión de entrada\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eHasta 250 V monofásica \/ hasta 430 V trifásica, 50\/60 Hz, máx. 10 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eTerminales de medición\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eL1, L2, L3, N, PE — máx. 250\/430 V, CAT III 600 V, máx. 10 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eToma de corriente\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eMáx. 250 V, CAT III 600 V, corriente permitida máx. 10 A; solo para fines de prueba\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eTerminales de salida de señal CP\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eAprox. ±12 V, CAT 0 en condiciones normales; máx. CAT II 600 V con respecto a PE en condiciones de cableado incorrecto o mal funcionamiento\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eSimulación PP\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eNC \/ 13 A \/ 20 A \/ 32 A \/ 63 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eEstados CP\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eA: VE no conectado · B: VE conectado, no listo · C: VE conectado, ventilación no requerida, listo · D: VE conectado, ventilación requerida, listo\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eSimulación de error\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eError CP “E” Encendido\/Apagado · Error PE \/ Fallo a tierra Encendido\/Apagado\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eProtección y clasificación\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eIP54 · Grado de contaminación 2 · Clase de protección II · Categoría de medición 600 V CAT III\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eFusible\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003e10 A \/ 250 V, 5×20 mm; protege la toma de corriente contra sobrecarga\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eEntorno de trabajo\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eTemperatura de trabajo 0–40 °C · Almacenamiento -10–50 °C · Humedad de trabajo 10–85 % RH sin condensación · Altitud máx. 2000 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eReferencia de cable StationCheck-J \/ 701U\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eCable de prueba tipo 1 para carga de CA Modo 3, adecuado para toma de corriente IEC 62196-2 Tipo 1 o cable fijo con conector de vehículo\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eReferencia física StationCheck-J \/ 701U\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eAproximadamente 832 g; tamaño del mango 210 × 110 × 55 mm, longitud sin cable de conexión\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n          \u003ctr\u003e\n\n\u003cth style=\"padding:10px;text-align:left;background:#f9fafb;border:1px solid #e5e7eb;\"\u003eReferencia del paquete manual\u003c\/th\u003e\n\n\u003ctd style=\"padding:10px;border:1px solid #e5e7eb;\"\u003eUnidad principal ×1 · cable de prueba ×1 · paquete portátil ×1 · manual de instrucciones ×1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n        \u003c\/tbody\u003e\n\n      \u003c\/table\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003csection style=\"margin-top:22px;\"\u003e\n    \u003ch3 style=\"font-size:22px;margin:0 0 10px;color:#111827;\"\u003eNotas técnicas para la resolución de problemas de EVSE de CA\u003c\/h3\u003e\n\n    \u003cp style=\"margin:0 0 10px;color:#4b5563;\"\u003eStationCheck es un simulador de diagnóstico para flujos de trabajo EVSE de CA. Simula estados de vehículos seleccionados, estados de corriente de cable, condiciones de PE y rutas de error de CP para que un operador capacitado pueda observar el comportamiento de la estación antes de involucrar un vehículo real.\u003c\/p\u003e\n\n    \u003cp style=\"margin:0;color:#4b5563;\"\u003eLa toma de corriente y los terminales de medición son solo para fines de prueba. No utilice la toma de corriente para alimentar otros dispositivos, y no cargue la toma de corriente y los terminales de medición al mismo tiempo. Utilice en entornos secos y limpios y siga las normas locales de seguridad eléctrica.\u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n  \u003csection style=\"margin-top:22px;\"\u003e\n    \u003ch3 style=\"font-size:22px;margin:0 0 10px;color:#111827;\"\u003ePreguntas frecuentes\u003c\/h3\u003e\n\n    \u003cdiv style=\"border:1px solid #e5e7eb;border-radius:12px;padding:14px;margin-bottom:10px;\"\u003e\n\n\u003cstrong\u003e¿StationCheck carga un vehículo eléctrico?\u003c\/strong\u003e\u003cp style=\"margin:6px 0 0;\"\u003eNo. StationCheck es un simulador de diagnóstico, no un cargador de vehículos eléctricos. Se utiliza para comprobar el comportamiento de las estaciones de carga de CA antes de que se involucre un vehículo real.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #e5e7eb;border-radius:12px;padding:14px;margin-bottom:10px;\"\u003e\n\n\u003cstrong\u003e¿Qué versión de StationCheck debo elegir?\u003c\/strong\u003e\u003cp style=\"margin:6px 0 0;\"\u003eElija por el conector de la estación de carga: StationCheck-J para SAE J1772 \/ Tipo 1 AC EVSE, StationCheck-T2 para Tipo 2 AC EVSE, y StationCheck-N para interfaces NACS \/ Tesla-style AC wallbox.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #e5e7eb;border-radius:12px;padding:14px;margin-bottom:10px;\"\u003e\n\n\u003cstrong\u003e¿Puede StationCheck probar un supercargador de Tesla?\u003c\/strong\u003e\u003cp style=\"margin:6px 0 0;\"\u003eNo. StationCheck-N es solo para comprobaciones de interfaz de CA NACS. No es para Supercargadores de Tesla, carga rápida de CC, autorización de aplicaciones, pago o pruebas de acceso a redes públicas de carga rápida.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #e5e7eb;border-radius:12px;padding:14px;margin-bottom:10px;\"\u003e\n\n\u003cstrong\u003e¿Quién debería usar este producto?\u003c\/strong\u003e\u003cp style=\"margin:6px 0 0;\"\u003eStationCheck está principalmente dirigido a instaladores capacitados, revendedores de EVSE, equipos de mantenimiento, operadores de flotas, operadores de propiedades y equipos de soporte que necesitan comprobaciones repetibles de estaciones de carga de CA.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n","brand":"ChargePapa","offers":[{"title":"ControlEstación-T2","offer_id":46975994429628,"sku":"StationCheck-T2-701E","price":376.6,"currency_code":"USD","in_stock":true},{"title":"StationCheck-N","offer_id":46975994462396,"sku":"StationCheck-N-701UT","price":418.6,"currency_code":"USD","in_stock":true},{"title":"Verificación de la estación-J","offer_id":46975994495164,"sku":"StationCheck-J-701U","price":418.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/3856\/3516\/files\/9022a705161ff42b7879d88f1fd6d0e8_7a094159-27a3-40f4-baee-13a3d710aa26.png?v=1781777309","url":"https:\/\/www.chargepapa.com\/es\/products\/chargepapa-stationcheck-simulador-de-diagnostico-ac-evse","provider":"ChargePapa","version":"1.0","type":"link"}